Air duct calculator - Ducting Calculators and Air Volume Converter. Nordfab can offer technical assistance with determining whether our ducting is best for your application and with designing duct installations. Please contact us with your requirements. Input CFM Input Velocity (FPM) Ideal Round Duct Diameter Duct Friction in Straight Duct. Calculate.

 
To calculate allowable leakage, you must know the system surface area, the required test pressure and the specified leakage class. System (or section) Surface Area. sq.ft. Test Pressure. (in.wg.) SMACNA Leakage Class*. Allowable leakage based on your input is: cfm. *SMACNA recommends using leakage classes in table below when the designer …. Nbes

Ducting Calculators and Air Volume Converter. Nordfab can offer technical assistance with determining whether our ducting is best for your application and with designing duct installations. Please contact us with your requirements. Input CFM Input Velocity (FPM) Ideal Round Duct Diameter Duct Friction in Straight Duct. Calculate.Jul 29, 2022 · Return air duct size for 1-5 ton ACs is 14” to 22” for round ducts and 13”x12” to 32”x12” for rectangular ducts. Use the return air duct size calculator below for accurate dimensions required for your air conditioner or heat pump. There is also a table of return air duct sizes for round and rectangular ducts for ACs from 1.5 to 5 tons. The velocity of an air duct with area 16 sq.ft and air flow of 10 CFM would be : V = 10 / 16 = 0.625 FPM. When converted to FPS, it is 0.0104 FPS. Air duct also termed as ductulator is a passage that is used to provide fresh air into rooms, buildings etc., Air ducts may be in circular, square and in rectangular shapes. Duct Calculator Elite https://apps.apple.com/us/app/duct-calculator-elite/id665701601Duct Size Chart. Do your own calculations and compare them to our chart – or use the chart for quick, accurate calculations for duct size based on CFM needed for a room. One size is given for round ducts, its diameter. You have two or three options for rectangular ducts that give you the same or nearly the same square footage per duct.Diameter of Air Duct Sizing =√ ( (576 × 8) / (3.14 × 15)) = 9.8911 inch. Online ducting calculator to find the diameter of duct size. Sizing of air duct can be done using Velocity Method, Constant Pressure Loss Method and Static Pressure Recovery Method.These calculators estimate the temperature drop (or rise) of air flowing in a duct or fluid flowing in a pipe. An example is the use of insulation to minimize temperature change (either temperature drop or rise) of a process fluid from one location to another(e.g. a hot fluid flowing down a pipe). Temperature Drop Calculator for Air DuctsCleaning helps not only remove them, but may also remove blockages that can help make your system run more efficiently. Keep reading to learn more about the cost of duct cleaning services. 2024 Duct Cleaning Costs. Calculate local project costs by entering your zip code. Typical Price Range. $ 450 - $ 1,000.Ordinary heating, ventilating, and air conditioning duct systems read air pressures at 0.4 psi or less, often much less. 1 psi equals 27.7 inches of water gauge; a common duct pressure of 0.25 inches water column is equal to (0.25 divided by 27.7 in-wc/psi) = 0.009 psi. Duct Pressure: Duct system is pressurized by three pressures: • Ducting Calculators and Air Volume Converter. Nordfab can offer technical assistance with determining whether our ducting is best for your application and with designing duct installations. Please contact us with your requirements. Input CFM Input Velocity (FPM) Ideal Round Duct Diameter Duct Friction in Straight Duct. Calculate. A duct size calculator, commonly known as a ductulator, depends on factors like the size of the space you’re heating or cooling, air flow …By multiplying air velocity by the cross section area of a duct, you can determine the air volume flowing past a point in the duct per unit of time. Volume flow is usually measured …Using the chart, you’ll see that for a 12” round flex duct, maximum CFM is 480 CFM or 500 CFM depending on the friction rate. Duct size for 115 CFM. Find the CFM closest to 115 in the table above. It will be found in different columns depending on the friction rate. If there isn’t an exact match, go up to the duct size.50°F (27.8°C) 2″ (50mm) Recommended Duct Insulation Thickness for Concealed Ducts. So, if my dew point is 77°F (25°C) and the supply air temperature is 59°F (15°C), the temperature difference is 18°F (10°C) which is below 30°F (16.7°C). Therefore, my duct insulation should be 1″ (25mm) thick.About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ...By multiplying air velocity by the cross section area of a duct, you can determine the air volume flowing past a point in the duct per unit of time. Volume flow is usually measured …While air duct cleaning and repair lengthens its life span, ductwork typically needs major replacement every 15 years to work properly. The national average cost for full ductwork replacement is $1,450–$8,000; however, the cost can range anywhere from $250–$12,000 depending on home size, system accessibility, and materials used.The smallest return air grille is usually starts at 4 inches by 4 inches. So, the next corresponding return air grille size includes 4×6, 6×6, 6×4, 8×6, 4×8 and so on. The largest return air grille is typically stops at 48 inches by 24 inches. Here are some examples of a standard return air grille: 4×4. 6×6.The friction loss in a 20 inches duct with air flow 4000 cfm can be estimated to approximately 0.23 inches water per 100 feet duct as shown in the diagram above. The air velocity can be estimated to approximately 1850 feet per minute. A major friction loss diagram for air ducts - Imperial units ranging <i>10 - 100 000 cfm</i>.An Air duct pressure drop calculation is essential for designing and operating HVAC (Heating, Ventilation, and Air Conditioning) systems. Understanding how to calculate pressure drops in air ducts allows mechanical engineers to design more efficient and effective systems, ensuring optimal airflow and comfort in residential and commercial … QUICK-GUIDE. Select the duct material from the drop-down list (most duct sizing tools are typically based on galvanised steel ducting by default) Enter the air flowrate in cubic feet per minute (CFM) Enter an internal duct size in inches (this must be limited to a maximum aspect ratio of 5:1 for the results to be valid) The resulting velocity ... Mar 25, 2024 · The ductulator calculator is a specialized tool used in the HVAC industry to determine the most efficient duct sizes for air distribution within a space. It helps calculate the perfect balance between duct size, air velocity, and airflow, ensuring the HVAC system operates at peak efficiency. This balance is crucial for maintaining comfortable ... Download duct static pressure calculator excel sheet XLS. Free spreadsheet program for air duct friction loss calculation. Download Free MEP Calculation Excel Sheets, AutoCAD Drawings, and Training Courses for HVAC, Firefighting, Plumbing and Electrical Systems Design.The average per-square-foot cost for duct cleaning is $0.20 to $0.40. Using this standard, a 1,200-square-foot house could run from $240 to $500, while a 3,000-square-foot one could range from $600 to $1,200. When pricing this way, cleaners usually include registers and the insides of the ducts themselves, along with the air handler and …Air duct pressure loss. Friction loss calculation is made in rectangular or round ventilation ducts. Fill in the form below. Unit system. : Duct type. : Duct position.How Much Does an HVAC Replacement Cost in 2024? Average Cost Range: $6,465 - $11,877. Use the calculator below for a more accurate local estimate. Use Modernize's 2024 cost calculator to get accurate HVAC replacement cost. Get local price ranges by zipcode for cooling, heating or both!Formula. The formula for air duct sizing involves the calculation of air velocity (V) and duct cross-sectional area (A) to determine the air volume flow rate (Q), expressed in cubic feet per minute (CFM). Q = A × V. This equation comes from the principle of continuity in fluid mechanics which states that for incompressible flow, the product of ...Mar 4, 2023 · Duct Sizing Calculator. The duct sizing calculation involves determining the proper ductwork size needed for an HVAC system. The formula used in this calculation is Q=VA, where Q is the airflow rate, V is the air velocity, and A is the area of the duct. Sep 30, 2023 · Duct load calculation involves determining the heating or cooling load that a duct system must handle. It includes factors like air temperature, humidity, and the area being served. The calculation is complex and is typically done using specialized software. Rectangular sheet metal duct = .07" on most metal duct calculators. 2900. 40x12. 100 31/2 x14 2200 38x10 220 31/2 x30 2350 40x10. Rectangular sheet metal duct = .07" on most metal duct calculators. 3050. 42x12. Duct Size Chart. Do your own calculations and compare them to our chart – or use the chart for quick, accurate calculations for duct size based on CFM needed for a room. One size is given for round ducts, its diameter. You have two or three options for rectangular ducts that give you the same or nearly the same square footage per duct.The Engineering ToolBox (2004). Air Duct Calculator. [online] Available at: https://www.engineeringtoolbox.com/air-duct-calculator-d_813.html [Accessed Day …Minor or Dynamic losses in duct systems are pressure losses caused by. Minor or dynamic pressure loss in air duct system components can be expressed as. Δpminor_loss = ξ ρ v2 / 2 (1) where. ξ = minor loss coefficient. Δpminor_loss = minor pressure loss (Pa (N/m2), psf (lb/ft2)) ρ = density of air (1.2 kg/m3, 2.336 10-3 slugs /ft3)The Duct Sizing Calculator is a hand held sliding calculator used for sizing supply and return duct systems using the equal friction, or velocity reduction design method. Front of calculator includes scales for friction, velocity, round duct size, weight per linear foot of round duct, surface area in square feet per lineal foot of round duct ...September 17, 2023 by GEGCalculators. Converting round to rectangular duct sizes depends on specific design factors. As a rough approximation, a round duct with a diameter of 6 inches might correspond to a rectangular duct of 8×4 inches, but these conversions vary based on project requirements. Precise calculations should be made using HVAC ...Duct and vent cleaning costs $25 to $45 per vent or $0.15 to $0.25 per square foot. Air duct sanitizing costs $70 to $150 more to prevent mold growth. An air duct inspection costs $80 to $180. Cleaning the HVAC system costs $60 to $370 more for a furnace or AC unit. Air duct cleaning cost - chart. Purchase ADI Ductulator. The ADI - Air Distribution Institute, was formed in 1947 to promote the use of fabricated steel duct pipe and fittings for air distribution products. Today the alliance of ADI member companies produce steel duct pipe and fittings designed to efficiently deliver conditioned air in your home and office. Dec 3, 2023 · The Duct Pressure Loss Calculator is an essential tool used to estimate the pressure drop or loss that occurs within a duct system due to various factors such as friction, length, diameter, velocity of airflow, and gravity. Its primary function is to calculate the pressure loss (ΔP) occurring in the duct, offering insights into the system’s ... Feb 16, 2023 · Calculate for each individual room. To calculate CFM, you need to know the size of your heating or cooling unit in tons. Multiply this number by 400, which is the average output of an HVAC unit. Then divide by the total square footage of your home. This will give you the multiplier for all your rooms’ CFM. While air duct cleaning and repair lengthens its life span, ductwork typically needs major replacement every 15 years to work properly. The national average cost for full ductwork replacement is $1,450–$8,000; however, the cost can range anywhere from $250–$12,000 depending on home size, system accessibility, and materials used.The kinematic viscosity of air is determined by the properties of air, just like the density of air. However, both values are based on a set air condition. In the case of duct static pressure calculation, the properties of air are set at 1 atmospheric pressure at 20°C. Friction Loss Factor, f. The friction factor (f) is calculated using the ... TO CALCULATE DUCT SIZE: Enter Air Quantity (Flow Rate) Enter either Friction Loss or Velocity. The software will automatically detect the calculation method. Click Calculate and refer to duct size box for results. Click Refresh for a new calculation. VariTrane Duct Designer streamlines duct design and improves calculation precision, letting you optimize your designs while obtaining a minimum pressure system. VariTrane Duct Designer enables you to organize the layout structure of your duct system and provides detailed engineering information on a section-by-section …Air duct cleaning redefines home health. Eliminating dirt, dust and microbial growth from your ductwork can improve indoor air quality while maintaining a cleaner home and increasing HVAC efficiency. Clean ducts mean less dirt in your home and air because ductwork is often the source and pathway for dust and biological contaminants.Section 5 - Air Distribution System Design This section provides an executive overview of duct system design procedures, additionally covering the use of a branch take off fitting at the end of a supply air trunk duct. Section 6 - Duct Sizing Calculations This section covers the duct system design procedures in detail.While air duct cleaning and repair lengthens its life span, ductwork typically needs major replacement every 15 years to work properly. The national average cost for full ductwork replacement is $1,450–$8,000; however, the cost can range anywhere from $250–$12,000 depending on home size, system accessibility, and materials used.Air Duct Calculator. Double-sided. Side 1 = standard ducloator with calculations for both round and rectangular duct. Side 2 = Continental vs competitive cross reference for some common GRDs and a Grille sizing chart. Qty 25/package. Purchase ADI Ductulator. The ADI - Air Distribution Institute, was formed in 1947 to promote the use of fabricated steel duct pipe and fittings for air distribution products. Today the alliance of ADI member companies produce steel duct pipe and fittings designed to efficiently deliver conditioned air in your home and office. The pressure drop across a valve can be calculated using the valve’s Cv (flow coefficient) value and the flow rate. The equation is: Pressure Drop (psi) = (Cv × Q^2) / (SG × ΔP) where Q is the flow rate (in gallons per minute), SG is the specific gravity of the fluid, and ΔP is the pressure drop across the valve.By knowing how to calculate static pressure in air duct systems, you can determine that the right push of air counteracts the resistance in airflow. In a static pressure calculation, we are looking for the push of air to exceed the resistance. Otherwise, the system won't be able to circulate air throughout the ducts. Formula. The formula for air duct sizing involves the calculation of air velocity (V) and duct cross-sectional area (A) to determine the air volume flow rate (Q), expressed in cubic feet per minute (CFM). Q = A × V. This equation comes from the principle of continuity in fluid mechanics which states that for incompressible flow, the product of ... Kurb Air Duct Calculator. ductulator.app. Calculation Method. Static Pressure Loss [inW/100ft] Air Flow [CFM] 3000 FPM. Round Duct Air Velocity. Infinity FPM. …CFM (10×12 Duct, 500 FPM) = 500 FPM × 10 Inches × 12 Inches / 144 = 416.67 CFM. We can see that the 10×12 duct generates 416.67 CFM of airflow at 500 FPM air speed. Now, we did a huge amount of calculations for these rectangular ducts at 1 FPM, 500 FPM, and 2000 FPM, and gathered all the results in this feet per minute to cubic feet per ...PRODUCT DETAILS. AIR DUCT SLIDE RULE CALCULATOR. Size: 4"x9.25". Material: Heavyweight coated calculator board. Production: Each order is custom manufactured with your company information and in your choice of colors. AIR DUCT WIZARD DUCTULATORS. Size: 8.5"x11" card with a 7.25" wheel. Materials: Heavyweight coated …Ducting Calculators and Air Volume Converter. Nordfab can offer technical assistance with determining whether our ducting is best for your application and with designing duct installations. Please contact us with your requirements. Input CFM Input Velocity (FPM) Ideal Round Duct Diameter Duct Friction in Straight Duct. Calculate.Example of big metal round and rectangular ducts (3,000+ CFM airflow). To figure out exactly how big ducts you need for central air conditioning systems, we have prepared complete CFM duct charts for all different kinds of ducts:. Duct sizing chart for flex ducts (round ducts with 5-20 inch diameter).; Duct sizing chart for metal ducts (round ducts …Calculation of duct insulation. Easy program which, by entering a few values, immediately calculates the surface area of the ducts and insulation of the aeraulic circuit under consideration. Valid for quadrangular and circular ducts. In addition to the thickness of the insulation, it is possible to enter waste values (percentage of materials ...1. Diameter converter, which converts circular diameters to equivalent rectangular ducts. 2. Ventilation parameter calculator allows the diameter, air speed, airflow and dynamic pressure of your installation to be calculated. 3. Pressure drop calculation tool for installations with straight sections and duct system elements. 4.The velocity reduction method can be used when sizing air ducts. Equivalent Diameter - Rectangular vs. Circular HVAC Ducts Rectangular equivalent diameter for air flows between 100 - 50000 cfm. Fluid Flow - Equivalent Diameter Convert rectangular and oval duct geometry to a equivalent circular diameter - online calculator with imperial and SI ...Enter 6" into the Duct Height (Optional) field. The results table show a 10"x6" duct. This calculator can also be used to simply convert round to rectangular or vice versa. It is unnecessary to consider the duct material, length, or air volume since it is just a physical, geometric calculation. Assume we have an 18" round duct.50°F (27.8°C) 2″ (50mm) Recommended Duct Insulation Thickness for Concealed Ducts. So, if my dew point is 77°F (25°C) and the supply air temperature is 59°F (15°C), the temperature difference is 18°F (10°C) which is below 30°F (16.7°C). Therefore, my duct insulation should be 1″ (25mm) thick.How Much Does an HVAC Replacement Cost in 2024? Average Cost Range: $6,465 - $11,877. Use the calculator below for a more accurate local estimate. Use Modernize's 2024 cost calculator to get accurate HVAC replacement cost. Get local price ranges by zipcode for cooling, heating or both!Sheet Metal Duct Friction Loss Calculator. 1. Enter Duct Airflow (CFM), Duct Velocity (FPM), Duct Length and the number of bends. 2. Read Round Duct Diameter (inches) and Friction Loss Per 100' of duct (inches of water). 1. Enter Friction Loss Per 100' of duct (inches of water), Duct Airflow (CFM), Duct Length and the number of bends.Return air duct size for 1-5 ton ACs is 14” to 22” for round ducts and 13”x12” to 32”x12” for rectangular ducts. Use the return air duct size calculator below for accurate dimensions required for your air conditioner or heat pump. There is also a table of return air duct sizes for round and rectangular ducts for ACs from 1.5 to 5 tons.Air Flow Conversion Calculator. CUI Devices' air flow conversion calculator can be used to convert between common units for volume air flow and air velocity flowing past a point in a specified area of duct. To use the calculator, enter your air velocity or volume air flow and duct area/type, select your units, click calculate air flow, and your ...A major friction loss diagram for air ducts - Imperial units ranging 10 - 100 000 cfm. Air Ducts - Major Friction Head Loss, Online Calculator Head loss or major loss in air ducts - equations and online calculator for rectangular and circular ducts - Imperial and SI units. Air Ducts - Sizing Required duct area vs. air flow. Air Ducts - Velocity ...Sep 30, 2023 · Duct load calculation involves determining the heating or cooling load that a duct system must handle. It includes factors like air temperature, humidity, and the area being served. The calculation is complex and is typically done using specialized software. Using the chart, you’ll see that for a 12” round flex duct, maximum CFM is 480 CFM or 500 CFM depending on the friction rate. Duct size for 115 CFM. Find the CFM closest to 115 in the table above. It will be found in different columns depending on the friction rate. If there isn’t an exact match, go up to the duct size.Duct Size Chart. Do your own calculations and compare them to our chart – or use the chart for quick, accurate calculations for duct size based on CFM needed for a room. One size is given for round ducts, its diameter. You have two or three options for rectangular ducts that give you the same or nearly the same square footage per duct.Volume is the cross-sectional area multiplied by the length of the duct.; Density is the density of the material the duct is made of.; Diameter is the diameter of the round or spiral duct.; Width and Height are the dimensions of rectangular, oval, or flat oval ducts.; Length is the length of the duct.; For insulated ducts, you calculate the weight …The air duct calculator, or “ductulator,” is a commonly used tool for designing and installing duct systems. Unfortunately, many designers and technicians receive limited instructions on its correct use. This lack of instruction frequently results in duct systems that fail to perform as intended. It’s typical to find that delivered airflow into … Enter the air flowrate in litres/second (can change to cubic metres/second by use of drop-down to the right of the input) Enter an internal duct diameter (this can be any number, it doesn’t need to be standard duct size) To get an idea of the equivalent rectangular duct size, adjust the aspect ratio. Note that only aspect ratio up to 5:1 are ... Highlights. Your air ducts deliver cool and hot air throughout your home. There are sheet metal, fiberglass-lined, fiberboard, and flexible ducts. Some signs you need a cleaning include dirty vents and a pest infestation. Air duct cleaning costs $380 on average and ranges between $270 to $490.The formula for air duct sizing involves the calculation of air velocity (V) and duct cross-sectional area (A) to determine the air volume flow rate (Q), expressed in cubic feet per …Perfect for one time or a limited number of HVAC projects. Includes residential load calculator, plus duct sizing, equipment selection and cost analysis software for one low price This software includes all the features and capabilities of the permanent version, however it will expire on your computer 60 days after purchase. Only $49. Purchase ADI Ductulator. The ADI - Air Distribution Institute, was formed in 1947 to promote the use of fabricated steel duct pipe and fittings for air distribution products. Today the alliance of ADI member companies produce steel duct pipe and fittings designed to efficiently deliver conditioned air in your home and office. The velocity reduction method can be used when sizing air ducts. Equivalent Diameter - Rectangular vs. Circular HVAC Ducts Rectangular equivalent diameter for air flows between 100 - 50000 cfm. Fluid Flow - Equivalent Diameter Convert rectangular and oval duct geometry to a equivalent circular diameter - online calculator with imperial and SI ...Knowledge is power, so although we can't always correct the problems we see with duct work, I'm hoping that with some knowledge we can make some little chang...PRODUCT DETAILS. AIR DUCT SLIDE RULE CALCULATOR. Size: 4"x9.25". Material: Heavyweight coated calculator board. Production: Each order is custom manufactured with your company information and in your choice of colors. AIR DUCT WIZARD DUCTULATORS. Size: 8.5"x11" card with a 7.25" wheel. Materials: Heavyweight coated …Undersized return air ducts result in the ducts and grills being more noisy than usual and the air conditioner components becoming stressed, thus reducing the lifetime of the unit. Use our handy return air duct size calculator or charts below to help you determine the correct return air vent size for your home.Calculate velocities in circular and rectangular ducts - imperial and SI-units - online calculator. Ducts or Pipes through Steel Joists - Maximum Sizes. Maximum sizes of …Duct Calculator Elite TM is an industry leading tool designed to simplify the job of duct sizing for HVAC professionals. This app allows users to calculate duct size, velocity, pressure drop, and flow rate for ductwork . Duct Calculator Elite TM features a highly intuitive interface which allows users to easily enter values with precision (without the …The Ultimate HVAC Duct Calculator Guide: Increase Efficiency and Improve Airflow. HVAC duct calculators play an essential role in determining the proper size of ductwork for heating, ventilation, and air conditioning systems. Properly sized ducts are critical to maintaining optimum airflow, improving energy efficiency, and ensuring the …Mar 4, 2023 · Duct Sizing Calculator. The duct sizing calculation involves determining the proper ductwork size needed for an HVAC system. The formula used in this calculation is Q=VA, where Q is the airflow rate, V is the air velocity, and A is the area of the duct. Duct-U-Lator. This app works as a Ductulator and Pressure Loss (friction) calculator which has the following functions. Converts Duct Shape or Size to Another. Determines Sizes for a Given Friction Rate. Determines Sizes for a Given Velocity. Determines Sizes for a Given Velocity and a Friction Loss Rate (simultaneous output) Using the chart, you’ll see that for a 12” round flex duct, maximum CFM is 480 CFM or 500 CFM depending on the friction rate. Duct size for 115 CFM. Find the CFM closest to 115 in the table above. It will be found in different columns depending on the friction rate. If there isn’t an exact match, go up to the duct size.PRODUCT DETAILS. AIR DUCT SLIDE RULE CALCULATOR. Size: 4"x9.25". Material: Heavyweight coated calculator board. Production: Each order is custom manufactured with your company information and in your choice of colors. AIR DUCT WIZARD DUCTULATORS. Size: 8.5"x11" card with a 7.25" wheel. Materials: Heavyweight coated …The Ductulator - Duct Sizing Calculator is a hand held rotating calculator used for sizing supply and return duct systems using the equal friction design method. This accurate, easy-to-use duct size calculator includes scales for friction loss per unit length, air volume, air velocity, round duct diameter and rectangular duct diameters.Nov 11, 2023 · The Duct Area Calculator is a powerful tool designed to help individuals and professionals in the HVAC industry determine the cross-sectional area of rectangular and circular ducts. This essential calculation aids in optimizing airflow, ensuring efficient ventilation systems, and maintaining optimal indoor air quality.

The Duct Sizing Calculator is a hand held sliding calculator used for sizing supply and return duct systems using the equal friction, or velocity reduction design method. Front of calculator includes scales for friction, velocity, round duct size, weight per linear foot of round duct, surface area in square feet per lineal foot of round duct .... Autotrek

air duct calculator

For 1000 CFM, we need 1650.12 FPM to 11,459.16 FPM, if we use 4-10 inch round ducts. This is quite an enormous air velocity (11,459.16 FPM is equal to 130 miles per hour (mph)). Now, let’s have a look at the 2nd part for rectangular air ducts, starting with the 2nd calculator: The Engineering ToolBox (2004). Air Duct Calculator. [online] Available at: https://www.engineeringtoolbox.com/air-duct-calculator-d_813.html [Accessed Day …The formula for air duct sizing involves the calculation of air velocity (V) and duct cross-sectional area (A) to determine the air volume flow rate (Q), expressed in cubic feet per … QUICK-GUIDE. Select the duct material from the drop-down list (most duct sizing tools are typically based on galvanised steel ducting by default) Enter the air flowrate in cubic feet per minute (CFM) Enter an internal duct size in inches (this must be limited to a maximum aspect ratio of 5:1 for the results to be valid) The resulting velocity ... TO CALCULATE DUCT SIZE: Enter Air Quantity (Flow Rate) Enter either Friction Loss or Velocity. The software will automatically detect the calculation method. Click Calculate and refer to duct size box for results. Click Refresh for a new calculation. Example 2.5 ton Duct System Diagram. Sizing for a 2.5 Ton unit, we start with a 16" supply at 875 CFM -1125 CFM. We then take a 7" and 5" run (-200 CFM) off of this section bringing the remaining total to 675 CFM - 925 CFM. A drop from 16" to 14" in now required to keep pressure and velocity up. Free HVAC Duct Sizing - in SI/Metric or US/Imperial units. Welcome to CalcuDUCT - the quick and easy way to size ducts for any HVAC application. Duct work attenuation. Calculate the attenuation in unlined and lined ducts. Note that the table and diagrams list the attenuation in dB/m. 13. ... The speed and attenuation of sound in moist air varies with sound frequency and air humidity. Sound Attenuation - …AIR DUCT CALCULATOR : by Michael J. Rocchetti PE Mechanical Engineer . Metric Units. Flow rate M^3/S: Velocity M/S: Pressure Pascals: Temperature C: Length Meter: Duct Material: Uncoated Carbon Steel: PVC Plastic Pipe (smooth) Aluminum (smooth) galvanized steel (medium smooth) galvanized steel (average smooth) fiberglass duct …Pull the airflow vertically to hit the friction loss line at 0.1 in.wg. Then, pull the line diagonally to the right and find the suitable duct diameter. 14″ round duct is less than ideal because the friction loss will be greater than 0.1 …The Duct Sizing Calculator is a hand held sliding calculator used for sizing supply and return duct systems using the equal friction, or velocity reduction design method. Front of calculator includes scales for friction, velocity, round duct size, weight per linear foot of round duct, surface area in square feet per lineal foot of round duct ...Jul 29, 2022 · Return air duct size for 1-5 ton ACs is 14” to 22” for round ducts and 13”x12” to 32”x12” for rectangular ducts. Use the return air duct size calculator below for accurate dimensions required for your air conditioner or heat pump. There is also a table of return air duct sizes for round and rectangular ducts for ACs from 1.5 to 5 tons. .